Planning Website

          PLANNING GUIDELINES

 

 Lot Densities

            Low Density                                       7,000 sq. ft. minimum

            Medium Density                                 3,000 sq. ft. to 6,999 sq. ft.

            High Density                                       below 3,000 sq. ft.
 

 Lot Frontages and Mean Depth

 

Lot frontages

Mean Depth

     Low Density- 7,000 sq. ft. min. (Detached House)

60 ft.

80 ft.

     Medium Density- 3,000 sq. ft. to 6,999 sq. ft.

     (Detached or Semi- Detached and Duplex)

40 ft.

60 ft.

     High Density- below 3,000 sq. ft.

     (Attached dwelling Units for Urban areas only

12 ft.

50 ft.

 

Room Densities

Apartments, Condominiums and Villas                      50 Bedrooms per acre

Hotels and Guest Houses                                          75 Bedrooms per acre

 

Plot Coverage

 

Description

%

Residential (Single Family)

Low Density 7,000sq.ft. min.

25

Medium Density 3,000 sq. ft. to 6,999 sq. ft.  

30

High Density below 3,000 sq. ft.                    

50

Residential (Multi Family)

Apartments, Condominiums, Villas                

30

Commercial (not within CBD)

Minimum 10,000 sq. ft.

60

Commercial (CBD not corner lot)

 

80

Commercial (CBD Corner Lot)

 

100

Industrial                                

Minimum 10,000 sq. ft.

60

Touristic                                 

Minimum 10,000 sq. ft.

60

        

 

 
 
 
 
 
Set Backs
           

Set Backs

Category

Requirements

Front Set Backs

Footpath         

Residential Access (27 ft. and 20 ft.)

Residential Collector (30 ft.)

Secondary and Primary roads (Highway)                              

10 ft. min.

10 ft. min.

15 ft. min.

20 ft. min. (for all classes except industrial which is 30 ft.)      

Side Set Backs

Low Density 7,000 sq. ft. min.

Medium Density 3,000 sq. ft. to 6,999 sq. ft

High Density below 3,000 sq. ft.       

8 ft. min.

6 ft. min.

4 ft. min.

NB: 1 ft. must be added to standard set back for each additional floor of building

Rear Set Backs

 

8 ft. min.

Soakaway 10 ft. min. from boundary

Set Backs from the High Water Mark (HWM)

Cliffs and Slopes of 1:1         

Slopes of 1:4, 1:20

Slopes of 1:2                                                                                                  

25 ft. from the HWM

50ft from the HWM

100 ft from HWM

WASCOs Pipeline Reserve

 

6 ft. on either side of the Pipeline

River and Ravine Buffer

River Buffer

Ravine Buffer                                    

50 ft. on either side of river

15 ft. on either side of ravine

 
 
 
 


 

          NB: For Requirements and Fees see the CHECKLIST
 


 

© Ministry of Physical Development, The Environment Government of Saint Lucia 2008. All rights reserved.
Disclaimer
Home - DCA Decisions - Contacts - Site map - Links - Contact us
  Search
Standards
Ministry of Physical Planning Logo